Generator Input power: Single-phase 220VAC Frequency: 40kHz range: 22-35kVp accuracy: &©|8804;1% Max current: 100mA Power 5kW Control AEC Internal protection: for over-current, over-voltage, over-heat and output short circuit X-ray tube High power rotating anode of dual-focus tube with Mo target and Be window Dual Focus: 0.1/0.3mm Target material Mo Target rotate 2800RPM Anode capacity 150kHU Filter Al (0.3mm) C-Arm Motorized Vertical movement 630mm Angle +145?~ -145?
Image receptor Bucky and holder 18?4 (cm) Fiber grid&©|65306; 5:1, 80L/cm Compression paddle Motorized Speed 3 speeds. Contact images: 18?4(cm) Vertical movement 268mm Max. Pressure: 18kg Measurement Auto thickness measurement
SS-3000 mamography System is mainly used to acquire X-ray images of human breasts for clinical diagnosis. It is a film-based mammography system and proves to be an effective solution for breast diseases. SS-3000 mammography system consists of the main body unit and the control console (see the picture of the system), including the key components of dual-focus X-ray tube, collimator, rotating anode starter and protection system, high-frequency and high voltage generator (frequency: 40KHz), tube filament heating system, breast compression device, supporting arm and other mechanical and electric devices. X-ray tube is one of the major components which decide the breast image quality. SS-3000 system uses a high power rotating anode of dual-focus tube with Mo target and Be window (bias dual-focus: 0.1mm/0.3mm) to ensure the clear images. The carbon-based bucky features high transmission rate, and high efficiency in blocking the scattered X-ray, which is also helpful for improving image quality. The automatic exposure control system is highly sensitive and quickly reactive, so the exposure is automatically adjusted according to the factures of age and thickness etc. High standard and high resolution image The test results of CIRS phantom are as follows: ***tial resolution: 20Lp/mm Density re |
Company: |
Sunshine Medical Equipment Co., Limited.
|
Contact: |
Ms. Eva Huang |
Address: |
No.91 Baixia RD. Nanjing, China |
Postcode: |
210011 |
Tel: |
86 15850644003 |
Fax: |
86 25 52157547 |
E-mail: |
|
|
|
|